the network the TRP-C38 will time out after 10 seconds and the default values will remain. When
DHCP is enabled, the IP address, Netmask and Gateway fields become inaccessible and cannot
be changed by the user.
IP Address
A static IP address can also be assigned in this section of the menu. A dynamic address
assigned by the DHCP server may change if the TRP-C38 looses the Ethernet connection or
power is removed. The host (client) communication software requests a connection to the
specific IP address of the serial server. If the DHCP reassigns a different IP address the software
will not be able to communicate with the hardware. It is recommended to use a static IP address.
A static IP address is permanent and will not change unless changed in the menu. In most cases
the network administrator establishes the static address to be used.
Netmask
The default LAN netmask is configured for a Class C address. This maybe reconfigured by the
user.
Gateway
The gateway IP address allows users to access the serial server from outside the LAN.
MAC Address
The MAC address is not adjustable. This is assigned in the factory. Every Ethernet device
manufactured has it own unique MAC address.
Version & Date
The currently loaded version of the firmware, and when it was released, are shown here.
Link Status
Link status automatically displays the type of Ethernet connection. It will either display 10 BaseT
or 100BaseTX in full duplex or half duplex. This will depend on the LAN, switches, hubs used in
the LAN topology.
Server Serial Port
This field indicates the number of the port for with serial server properties are currently being
displayed. Changing the number in this field will cause all the other fields to display the
properties for the specified port. Note, however, that before changing ports, any change to
properties must be updated (Saved) or the serial server will not retain them.
Baud Rate
The serial port baud rate on the TRP-C38 must match the serial baud rate of the connected
device unless using Virtual COM mode. In Virtual COM mode the software program will establish