14
serial settings.
Data/Parity/Stop
This setting will have to match the data format of the connected device unless using Virtual COM
mode. In Virtual COM mode the software program will establish serial settings.
Flow Control
The flow control setting must match the connected serial device unless using Virtual COM mode.
In Virtual COM mode the software program will establish serial settings.
Protocol
Select TCP or UDP protocol. If the application does not require a UDP connection, select TCP.
TCP guarantees reliable communication with error checking whereas UDP provides faster
transmission.
When UDP mode is chosen the
Serial timeout
,
TCP alive timeout
,
Connection mode
,
Connection
at
,
Maximum connection
and
Remote IP address
fields are replaced with the following three
fields
: Destination IP address range
,
Port number
and
Source IP address range
. In this mode the
server can be configured to broadcast data to and receive data from multiple IP addresses. Four
IP address range fields are provided.
Serial Timeout
Default is 0, or no timeout. Setting timeout to any value between 1 and 65535 seconds activates
it. If communications are idle for specified timeout value the serial server will reset and make
itself available for another connection.
TCP Alive Timeout
This monitors TCP activity. If TCP activity stops for the length of time specified in this field the
connection will be closed. This field can be set to any value between 0 and 255 minutes. If zero,