or no value, is entered into this field the server will not disconnect.     

 

Connection Mode

 

The Connection mode field has three options, Server, Client and Client (no heartbeat). When 

Client or Client (no heartbeat) is selected, the 

Connection at

 field automatically becomes active 

(allowing the user to select Power up or Data arrival).   

• When using the Virtual COM Port feature, select Server.   

• When using a TCP or UDP Socket program, select Server.   

• When using Paired Mode communication between two serial servers set up one as a Client 

and the other as a Server.   

• When connecting to a server that does not support Heartbeat, select Client (no heartbeat).   

 

Delimiter HEX1 and Delimiter HEX 2 

These two fields allow the user to enter two ASCII characters (in hex format) that delimit the 

beginning and end of a message. When a message with both these delimiters is received at the 

serial port, the data contained in the serial buffer is placed in an Ethernet packet and sent out the 

Ethernet port. If only Delimiter 1 is set (Delimiter 2 is zero or blank), upon receiving Delimiter 1 

the TRP-C38 will put all the data in the serial buffer in an Ethernet packet and send it out the 

Ethernet port. If serial data greater than 1 kilobyte is received it will automatically be placed in an 

Ethernet packet and sent out the Ethernet port.     

 

Force Transmit

 

This field allows the user to set a maximum time limit between transmissions of data. The value 

set in this field multiplied by 100 ms determines the Force Transmit time. When the elapsed time 

reaches the time configured in this field, the TCP/IP protocol will pack the data currently in the 

serial buffer into a packet and send it out the Ethernet port.   

   

Port Status

 

This field indicates whether a serial port is connected to a server or by a client.     

 

TCP/UDP Port

 

The TCP/UDP Port defines a communication port number. In all modes of operating, Virtual 

COM, Direct IP, and Paired modes, both the TCP/UDP Client and server port settings must 

match.    

For example the Virtual COM defaults setting TCP/UDP Port # 4000. If the port # of the TRP-C38 

is changed to 4001, the Virtual COM TCP/UDP Port will have to be changed to 4001.       

 

Serial Port Mode

 

  This allows configuration of the serial server for the following modes of operation:   

   

• Console – When this mode is selected and the server is updated, a PC running a 

           communication program such as Hyper-terminal can communicate with the 

Содержание TRP-C38

Страница 1: ...2 86781172 Web www trycom com tw Copyright Copyright Notice The information in this manual is subject to change without prior notice in order to improve reliability design and function and dosed not...

Страница 2: ...er Utility 8 6 Updating a TRP C38 Existing Installation 10 7 How to configure TRP C38 11 7 1 Using TRP C3X Manager 11 7 1 1 Searching LAN for TRP C38 11 7 1 2 Configuring Server Properties 12 7 2 Usin...

Страница 3: ...re to ensure a reliable communicating connection 1 1 Features Supports RS 232 serial interface In Server mode supports individual client sessions for security Virtual COM drivers for Windows NT 98 ME...

Страница 4: ...s and the functionality of the LED s are also provided 2 1 Panel layout A TX RX LED COM A RS232 Transiting Receiving B TX RX LED COM B RS232 Transiting Receiving C TX RX LED COM C RS232 Transiting Rec...

Страница 5: ...all plate A crossover Ethernet cable can be used to make a connection directly to the NIC Network Interface Card on a PC or laptop 2 5 Reset Button The reset button can be found between the switch and...

Страница 6: ...ion Pin RS 232 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI 3 Default Settings Model Number TRP C38 Password Blank DHCP Disable IP address 192 168 1 1 Netmask 255 255 255 0 Gateway 192 168 1 2...

Страница 7: ...erminal DC input simultaneously STEP2 Connect TRP C38 with internet port Ethernet Hub or Switch by RJ45 LAN cable If the cable properly connects the LINK LED will light up Green 100MB Yellow 10MB STEP...

Страница 8: ...en this is completed a window will list the devices making them available for configuration Configuring the serial server to meet your LAN and application requirement is an easy process with the avail...

Страница 9: ...ess will be shown until complete STEP5 Click Finish when the Install Shield Wizard Complete screen appears When the installation is complete user may access to the Manager software in the program file...

Страница 10: ...Software The TRP C3X Manager software performs several functions A Searching for TRP C38 connected to the network B Displaying and changing the configuration of TRP C38 C Installing virtual COM ports...

Страница 11: ...and after a few seconds the Serial Server List will display all TRP C31 32 34 serial servers on the network B To manually initiate a search for servers on the menu side bar select Searching Server but...

Страница 12: ...desired application Server Name The server name is user configurable It is recommended users with more than one TRP C38 connected to the LAN assign a new name to each When the Manager software search...

Страница 13: ...ss to be used Netmask The default LAN netmask is configured for a Class C address This maybe reconfigured by the user Gateway The gateway IP address allows users to access the serial server from outsi...

Страница 14: ...unication with error checking whereas UDP provides faster transmission When UDP mode is chosen the Serial timeout TCP alive timeout Connection mode Connection at Maximum connection and Remote IP addre...

Страница 15: ...limiter 1 is set Delimiter 2 is zero or blank upon receiving Delimiter 1 the TRP C38 will put all the data in the serial buffer in an Ethernet packet and send it out the Ethernet port If serial data g...

Страница 16: ...ld becomes active allowing the TRP C38 acting as a client to connect to the server either on Power up or on Data Arrival first character arriving Maximum Connection This field allows the user to confi...

Страница 17: ...application A serial connection is made between a COM port on the PC and the TRP C38 serial port A with a null modem cable In console mode the serial port defaults to an RS 232 interface The TRP C38 s...

Страница 18: ...electricfilm eu V NZ RI 0364 710319 electricfilm eu gmail com SUPORT TEHNIC 0788 250583 cele mai sensibile 18 STEP2 Select New Connection and Enter a name click OK STEP3 Enter the COM Port number tha...

Страница 19: ...et window displays the same configuration information shown in Console Mode and allows server properties to be configured See chapter 6 for details on Server Properties Ensure the PC and TRP C38 are c...

Страница 20: ...oara 3 Apt 42 Cluj Napoca Cluj 400445 www electricfilm eu V NZ RI 0364 710319 electricfilm eu gmail com SUPORT TEHNIC 0788 250583 cele mai sensibile 20 STEP2 Click the OK TRP C38 firmware setting will...

Страница 21: ...perties can be set up using three browser pages See chapter 6 for details on Server Properties In Internet Explorer type the IP Address of the Serial Server into the address field near the top of the...

Страница 22: ...Virtual COM Port STEP1 On the Desk Top select Start Programs Trycom Install Virtual COM STEP2 Select the Search all reachable servers check box then click OK STEP3 The Install Virtual COM program wil...

Страница 23: ...tion window stating that the drivers have not been tested by Microsoft may appear Select Continue Anyway to proceed with the installation STEP5 When Virtual Com installation completed click close on t...

Страница 24: ...justments and select OK to complete the changes 8 2 1 Configuration with Device Manager STEP1 On the Desk Top select Start Settings Control Panel Select the System Icon when the Control Panel window o...

Страница 25: ...isoara 3 Apt 42 Cluj Napoca Cluj 400445 www electricfilm eu V NZ RI 0364 710319 electricfilm eu gmail com SUPORT TEHNIC 0788 250583 cele mai sensibile 25 STEP4 Select the Configuration tab From here t...

Страница 26: ...e removed in the Device Manager of Windows 98 ME NT 2000 and XP Windows 98 users will also find a Remove Virtual COM feature in the programs file 8 4 Removing the Virtual COM port with Manager Softwar...

Страница 27: ...ve been made move to the Configuration screen select Save and press Enter The restart message will appear Select Yes to save changes This is necessary to write the settings to the server 9 Application...

Страница 28: ...port number The virtual COM driver is a TCP or UDP client 9 3 Paired Mode Paired mode is also called serial tunneling When this type of configuration is selected additional software will not have to...

Страница 29: ...n every 5 seconds until communications is established again The Heart Beat feature is available to use with the Virtual COM Mode Paired Mode and Direct IP Mode This is not available when using a UDP a...

Страница 30: ...NZ RI 0364 710319 electricfilm eu gmail com SUPORT TEHNIC 0788 250583 cele mai sensibile 30 11 RS232 422 Loop Test STEP1 Adjust the TRP C38 s Switch to the ON OFF STEP2 Run the Install Virtual Com an...

Страница 31: ...hen the Hyperterminal status will show your port settings such as 9600 8 N 1 save this Hyperterminal connection Next you open your saved Hyperterminal connection everything will be fine Q What should...

Страница 32: ...ange Please check hardware switch or server properties page to see if the serial port mode of the port1 is set to console Please change it to other mode then its parameter can be changed Q Why the par...

Отзывы: