*If watchdog is in enable , send the Host Ok!”command before watchdog timeout (B) the
watchdog will re-count, PWR LED will flashing after watchdog timeout.
8-23.Read power on/safe value
Command
~ID4V(CHK)(cr)
Syntax
description
~
First Leading code
ID
Address of setting module 00-FF(HEX)
4
Read power on or safe mode I/O status
V
V=P: Power on mode I/O status
V=S: Safe mode I/O status
CHK
Checksum
(cr)
Carriage return
Response
!IDABCD
AB=DO0~DO7
CD=DI0~DI7
?ID(CHK)(cr)
Command invalid
Example:
Send Command:~014S……….Read safe mode digital output status.
Response:” !01080F”………. . Command valid, safe mode digital IO status is ”080F”.