Example:
Send command:$01M…Read the TRP-C29UM’s name.
Response:”!01TRPC29……. The module’s name is “TRPC29.
8-15.Read the module’s firmware version
$IDF(CHK)(cr)
Syntax
description
$
First Leading code
ID
Address of setting module 00-FF(HEX)
F
Command for leading module’s version
CHK
Checksum
(cr)
Carriage return
Response
!IDMODYYMMDD
Mod: The module type
YY: Year
MM: Month
DD: Date
?ID(CHK)(cr)
Example:
Send command:”$01F”…Read the TRP-C29UM’s version.
Response:”!01C29M0703 The TRP-C29UM’s version date is “11/06/2009”.
8-16. Read the module reset status