Command
ID 46 00 00 (CRC)
Syntax
Description
ID
Address of setting module 1~247
46
Function code
00
Read module’s name
00
Reserved code
Response
ID 46 00 00 0C 29 00 (CRC)
ID 46 00 00 ….Module command Line
0C 29 :Module’s Name is C29
ID C6 00(CRC)
ID C6 (CRC) C6:Function Code 00: Reserved code
EX: Send Command:”01 46 00 00”…….Read the TRP-C29U’s name
Response:”01 46 00 00 0C 29 00 “……Module’s name is C29
Error Response: “01 C6 00”……Error code
10-2.Set up the module’s address
Command
ID 46 04 IP 00 00 00 (CRC)
Syntax
Description
ID
Address of setting module 1~247
46
Function Code
04
Set up module’s ID
IP
New module’s ID
00 00 00
Reserved code
Response
ID 46 04 00 00 00 00 (CRC)
ID 46 04 00 00 00 00 ….Change module ID OK!
ID C6 00(CRC)
ID C6 (CRC) C6:Function Code 00: Reserved code
EX: Send Command:”02 46 04 03 00 00 00”…….Set up the new ID is “03”.
Response:”01 46 04 00 00 00 00 “……New ID is 03.
Error Response: “01 C6 00”……Error code.
10-3.Read the module’s configuration
37