Command
ID 46 05 00 (CRC)
Syntax
Description
ID
Address of setting module 1~247
46
Function Code
05
Read module’s configuration
00
Reserved code
Response
ID 46 05 00
BD
00 00 00 00 00 00 (CRC)
ID 46 05 00 ……Module command Line
BD
:Baud Rate
See 8-2
00 00 00 00 00 00 : Reserved code
ID C6 00(CRC)
ID C6 (CRC) C6:Function Code 00: Reserved code
Example:
Send Command:”01 46 05 00”…….Read TRP-C29U’s configuration.
Response:”01 46 05 00
06
00 00 00 00 00 00 “……06:BD=9600…See 8-2 baud rate table.
Error Response: “01 C6 00”……Error code.
10-4.Set up the module’s configuration
Command
ID 46 06 00 BD 00 00 00 00 00 00 (CRC)
Syntax
Description
ID
Address of setting module 1~247
46
Function Code
06
Set up module’s configuration
00
BD
00 00 00 00 00 00
BD
: Baud-Rate….See 8-2
Response
ID 46 06 00 00 00 00 00 00 00 00 (CRC)
ID 46 06 00 ……Module command Line
00 00 00 00 00 00 00 00 : Reserved code
ID C6 00 (CRC)
ID C6 (CRC) C6:Function Code 00: Reserved code
Example:
Send Command:”01 46 06 00
0A
00 00 00
00 00 00”…….Set up TRP-C29U’s configuration.
Response:”01 46 06 00 00 00 00 00 00 00 00 “…Set up OK!.
Error Response: “01 C6 00”……Error code.
*Baud-Rate set to 115200
10-5.Read the module’s Firmware
38