![Trycom Technology TRP-C29U Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/trycom-technology/trp-c29u/trp-c29u_user-manual_1177632021.webp)
8-1. Configure TRP-C29U
Command
%IDNNPPBBDD(CHK)(cr)
Syntax
Description
%
First leading code
ID
Address of setting module 00-FF(HEX)
NN
New address of setting from 00-FF(HEX)
PP
The Digital I/O module type define to 40
BB
Set new baud rate
(See 8-2)
DD
Data format
(See 8-3)
CHK
Checksum
(cr)
Carriage return
Response
!ID(CHK)(cr)
Command valid
?ID(CHK)(cr)
Command Invalid
8-2. Baud rate setting (BB)
8-3. Data format setting (DD)
Bit
7
6
5
4
3
2
1
0
Function
Input counter
*0:Rising
1:Falling
Checksum
*0:Disable
1;Enable
0
0
0
0
0
Counter Display Mode
*:0:Normal (Dec)
1:Engineer Mode (Hex)
*Default
Example:
Send command:”%0001400600”…
New ID is “01”,D I/O type is “40” ,Bard-Rate:9600 ,Checksum setting disable is “00”,
Response:”!01”.
*If you adjust the switch to “ON ON”, the ID will be back to *INIT
Example:
Send command:”%000340054”
New ID=“03”,Bard-Rate=“4800”,Checksum=“Enable”,Response:”!03”.