1
Rear safety doors (hinged
doors)
2
Lateral safety doors (sliding
doors)
3
Anti-glare protection
4
EMERGENCY STOP push-but-
ton
5
Operating unit with foot switches
6
Operating-mode key switch
7
Upper cover with exhaust hood
8
Operating elements on the
robot welding arm
9
Power source
10 Exhaust system
11 Extendible partition wall
Danger zones and safeguarding device
Fig. 105422
The operating-mode key switch is located laterally on the central
operating unit.
Unauthorized operation of the machine in the operating
modes "Manual mode" and "Program test" by operating
personnel!
Injuries due to unintended use of the machine.
Ø
Remove the key in automatic mode and store it safely.
Ø
Have setting and test work performed by instructed welding
specialists.
B1154en
2020-09-01
Measures to be taken by the manufacturer
1
‐
17
Operating-mode key switch
WARNING