3.
Compressed air supply
Note
The connection point is indicated on the installation plan using
this symbol.
The machine is supplied with compressed air for:
■
Anti-glare protection
■
Linear axis
Properties
Requirement
Required network pressure
6 bar to 7 bar (87 to 101.5 psi)
Air consumption (required volume
flow rate according to ISO 1217 or
DIN 1945)
about 0.1m
3
/h (0.06 cfm)
Compressed air supply connected loads
Tab. 2-7
Characteristic
Requirement
Inside diameter of the connection
line
13 mm (1/2 ")
Inside diameter of main line
13 mm (1/2 ")
Length of the connecting line
No limit
Supply lines compressed air supply
Tab. 2-8
Characteristic
Requirement
Quality
class
Recommendation
Dust-free
Max. particle size:
≤5 μm
Max. particle den-
sity: ≤5 mg/m
3
3
Air filter in front of
the system
Condensate-free
Cooled down to
+2°C (35.6°F),
pressure dew point
3
Cold dryer
Oil-free
Max. oil content:
≤1 mg/m
3
3
Oil-free sealing
screw-type com-
pressor with
active carbon filter
Compressed air properties
Tab. 2-9
3.1
Compressed air connection
The compressed air inlet is located on the right side of the
machine under the electrical cabinet.
B1154en
Compressed air supply - Version 2
2
‐
9
Compressed air supply
connected loads
Supply lines for
compressed air supply
Compressed air properties
at the tapping point