background image

Triton Showers 

Triton Road 

Nuneaton 

Warwickshire  CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

TRITON reserve the right to change product specification without prior notice. E&OA. © TRITON SHOWERS 20

1

1

Customer Service: 

0844 980 0750

Trade Installer Hotline: 

0844 980 0730 

Fax: 

 

0844 980 0744

www.tritonshowers.co.uk 

E-mail: [email protected]

Extended Warranty AVAILABLE NOW. Call 0844 980 0740 for more details.

UK SERVICE POLICY

In the event of a product fault or complaint occurring, the 

following procedure should be followed:

1.

  Telephone Customer Service on 

0844 980 0750

 having available, 

your details including post code, the model number and power 

rating of the product, together with the date of purchase.

2.

  Based on information given over the telephone, a Triton Customer 

Service Advisor will attempt to diagnose the fault and confirm 

whether a site visit from a qualified service engineer is required.

3.

  All products attended to by a Triton service engineer must 

be installed in full accordance with the Triton installation 

guide applicable to the product. 

(Every product pack contains 

an installation guide, however, they can also be bought via our 

Customer Service Spares Department)

.

4.

  Our engineer will require local parking and if a permit is required 

this must be available to the engineer on arrival at the call. 

5.

  It is essential that you or an appointed representative 

(who must 

be over 18 years of age)

 is present for the duration of the service 

engineer's visit. If the product is in guarantee you must produce 

proof of purchase.

6.

  Where a call under the terms of guarantee has been booked and 

the failure is not product related 

(i.e. scaling and furring, incorrect 

water pressure, pressure relief device operation or electrical/

plumbing installation fault)

 a charge will be made. A charge will 

also be issued if nobody is at home when the service engineer 

calls or adequate parking/permit is not available.

7.

  If the product is no longer covered by the guarantee an up front 

fixed fee will be charged before the site visit.

8.

  Should proof of purchase not be available on an “in-guarantee” 

call, or should the service engineer find that the product is no 

longer under guarantee, the engineer will charge the same 

fixed price and the customer will be expected to pay the 

engineer before he leaves. If payment is not made on the day an 

administration charge will be added to the fixed charge.

9.

  If a debt is outstanding from a previous visit, or from any other 

Triton purchase. Triton reserves the right to withhold service until 

the debt has been settled.

10.

 Triton takes the health, safety and wellbeing of its employees very 

seriously and expects customers to treat all staff members with 

respect. Should any employee feel threatened or receive abuse, 

either verbally or physically, Triton reserves the right to withhold 

service and will support the employee with a legal prosecution.

Replacement Parts Policy

Availability:

 It is the policy of the manufacturer to maintain parts 

availability for the duration of production and a period of five years 

thereafter, in accordance with industry standards.
Spare parts are available via our website, 

www.tritonshowers.

co.uk

, or by telephoning Triton Customer Service Spares Department. 

Payment should be made by credit/debit card 

(excluding American 

Express or Diners Card)

.

Payment can also be made by pre-payment of a pro forma invoice by cheque or money order.

TRITOn STandaRd GUaRanTEE

Triton guarantee this product against all 

mechanical and electrical defects arising from 

faulty workmanship or materials for a period of 

two years for domestic use only, from the date of 

purchase, provided that it has been installed by 

a competent person in full accordance with the 

fitting instructions. 
Any part found to be defective during this 

guarantee period we undertake to repair or replace 

at our option without charge so long as it has been 

properly maintained and operated in accordance 

with the operating instructions, and has not been 

subject to misuse or damage. 
This product must not be taken apart, modified or 

repaired except by a person authorised by Triton. 

This guarantee applies only to products installed 

within the United Kingdom and does not apply to 

products used commercially. This guarantee does 

not affect your statutory rights. 

What is not covered: 
1.

  Breakdown due to: 

a)

 use other than domestic 

use by you or your resident family; 

b)

 wilful act 

or neglect; 

c)

 any malfunction resulting from the 

incorrect use or quality of electricity, gas or water 

or incorrect setting of controls; 

d)

 failure to install 

in accordance with this installation guide. 

2.

  Repair costs for damage caused by foreign 

objects or substances.

3.

  Total loss of the product due to non-availability 

of parts.

4.

  Compensation for loss of use of the product or 

consequential loss of any kind.

5.

  Call out charges where no fault has been found 

with the appliance.

6. 

Call out charges where the water supply cannot 

be isolated, this includes consequential losses 

arising from unserviceable supply valves.

7. 

The cost of repair or replacement of pressure 

relief devices, showerheads, hoses, riser rails 

and/or wall brackets, isolating switches, 

electrical cable, fuses and/or circuit breakers or 

any other accessories installed at the same time.

8. 

The cost of routine maintenance, adjustments, 

overhaul modifications or loss or damage arising 

therefrom, including the cost of repairing 

damage, breakdown, malfunction caused by 

corrosion, furring, pipe scaling, limescale, 

system debris or frost.

4-1-201

1

Содержание TAMAS

Страница 1: ...Installation and operating instructions 2180821C January 2011 INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER TAMAS thermostatic electric shower ...

Страница 2: ...C O L D HOT COLD 0 1 2 HEATER ELEMENTS USED HEATER ELEMENTS USED NONE OF THE ELEMENTS USED 0 1 2 1 OF THE ELEMENTS USED HEATER ELEMENTS USED 2 OF THE ELEMENTS USED 0 1 2 H O T HOT COLD To START the shower press the start stop button and water will flow from the shower The showers power light will illuminate 1 2 3 4 To STOP the shower follow steps 3 and 1 in reverse To START or STOP your shower To ...

Страница 3: ...ensions and entry points 3 Introduction 4 Specifications 4 Important advice to users 4 Electrical requirements 5 6 Water requirements 7 User Operating Instructions 8 10 INSTALLING THE SHOWER Siting of the shower 11 Fitting the shower to the wall 12 13 Plumbing connections 14 Electrical connections 15 Shower drain pumps not supplied 13 14 COMMISSIONING 16 17 Connecting the PCB cable Replacing the c...

Страница 4: ...t to operate 1 9 This product is not suitable for mounting into steam rooms or steam cubicles 2 PLUMBING 2 1 The plumbing installation must comply with Water Regulations Building Regulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS 6700 2 2 The supply pipe must be flushed to clear debris before connecting to the show...

Страница 5: ...Fig 2 Fig 1 218mm 93mm 345mm ENTRY POINTS DIMENSIONS WATER Left Top Side Back Right Bottom Side Back CABLE Left Top Bottom back Right Back Back Back Others Others Inlet connection 15mm diameter Outlet connection BSP male thread ...

Страница 6: ...ter temperature The slower the flow the hotter the water becomes the faster the flow the cooler the water b During winter the mains water supply will be cooler than in the summer The flow rate will vary between seasons at any one temperature setting At different times of the year you may have to adjust the position of the temperature control to maintain your desired temperature setting c The therm...

Страница 7: ...to a ring main spur socket outlet lighting circuit or cooker circuit 3 1 The electrical supply must be adequate for the loading of the unit and existing circuits 4 Check your consumer unit main fuse box has a main switch rating of 80A or above and that it has a spare fuse way which will take the fuse or Miniature Circuit Breaker MCB necessary for the shower Fig 4 4 1 If your consumer unit has a ra...

Страница 8: ...allation 9 3 In any event it is essential that individual site conditions are assessed by a competent electrician in order to determine the correct cable size and permissible circuit length E 002 A when the switch is in the OFF position and the wiring must be connected to the switch without the use of a plug or socket outlet 6 2 The switch must be accessible and clearly identifiable but out of rea...

Страница 9: ...Isolating stopvalve Mains water supply Shower unit Switch may be wall mounted in accordance with IEE regs Mains electric supply via double pole switch Double pole isolating switch Separate permanently connected supply from consumer unit Diagrammatic view not to scale The installation must be in accordance with Water Regulations Bylaws Supply Source Mains pressure cold water only Minimum running pr...

Страница 10: ... Maximum The shower will start on Maximum The two Heat setting indicators will light Economy setting 1 heat indicators lit Economy Press the Maximum Economy button once and one indicator will go out This shows that the shower is now in Economy mode Cold setting Cold indicator lit Cold Press the Cold button once and the cold setting indicator will light This shows that the shower is now in Cold mod...

Страница 11: ...an be left where it is as the preferred setting To decrease the shower temperature Turn the temperature control anti clockwise this will increase the flow of water through the shower and make the water colder To increase the shower temperature Turn the temperature control clockwise this will decrease the flow of water through the shower and make the water hotter When the start stop button is press...

Страница 12: ...res the power to the elements Phased shutdown In use every time the Start Stop button is pressed power is switched off to the elements Water will continue to flow for a few seconds flushing out any remaining hot water This makes sure the next immediate user will not receive a slug of hot water if standing under the showerhead when starting the shower Safety cut out The unit is fitted with an over ...

Страница 13: ...r at a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed appliance The use of the supplied gel hanger hose guide will in most cases meet this requirement but if the showerhead can be placed within a bath basin or shower tray then a double check valve or similar MUST be fitted in the supply pipework to prevent back flow Pressure relief safety device...

Страница 14: ... the mains water and electric cable can be found on Page 3 NOTE Deviations from the designated entry points will invalidate product approvals After choosing the site for the shower use the backplate to mark the three fixing holes the position of which are shown in fig 10 If bottom entry has been chosen fit the appropriate cut out in the top of the backplate fig 11 If top entry has been chosen fit th...

Страница 15: ... position DO NOT fully tighten the screws at this stage as the fixing holes are elongated to allow for out of square adjustment after the plumbing connections have been completed NOTE If entry is from the rear the nut of the compression fitting will be partially behind the surface of the wall fig 13 This area must be left clear when plastering over the pipework as to make the nut accessible for fu...

Страница 16: ...the water supply should maintenance or servicing be necessary Important Before completing the connection of the water supply to the inlet of the shower flush out the pipework to remove all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the mains water supply long enough to clear the debris to waste Procedure Turn off water supply either at the main...

Страница 17: ...uctor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable MUST be secured either by routing through conduit in trunking or by embedding in the wall in accordance with IEE regulations The use of connections within the unit or other points in the shower circuit to supply power to other equipment i e extractor fans pumps etc will invalidate the g...

Страница 18: ...T connect the 10 way ribbon cable at this stage Fig 17 Fig 16 Temperature control Offer the cover to the unit Carefully locate the cover tags into the guide pockets on the backplate and make sure the wires are not trapped Guide the cover into position so that the control spindle locates correctly minor adjustment may be necessary to align the control and spindle Should any difficulty arise recheck...

Страница 19: ...n as shown in fig 19 It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris is being flushed from the shower When a smooth flow of water is obtained turn the temperature control from minimum flow to maximum flow and back again several times to release any trapped air from within the unit Once the flushing out has been completed switch off the electrici...

Страница 20: ...is preformed to fold flat when the cover is fitted Guide the cover into position so that the knob spindle locates correctly minor adjustment may be necessary to align the knob and spindle Should any difficulty arise re check the points above While applying slight pressure to the cover secure in position with the retaining screws Turn the electric supply back on at the isolating switch The Power in...

Страница 21: ...tting anti clockwise and remove from the housing Inspect the O ring for damage when the filter is removed When cleaning the filter DO NOT use a sharp object as it will cause damage It is preferable to use an old toothbrush or similar To reassemble follow the procedure in reverse Make sure that the sealing O ring is in place and DO NOT over tighten the retaining screw on reassembly Instructions for...

Страница 22: ...assembly P26810803 6 Thermostatic P26810807 Temperature control 7 Pressure relief device PRD 82800450 8 Terminal block wires S26811001 9 Water inlet 7054085 10 Water Outlet P26810802 11 Main Trimplate White 7054071 Black 7054075 12 Signal wire 2160611 13 Cover ass including ON OFF switch PCB White S26820602 Black S26820603 Bottom pipe trim White 7054073 Black 7054077 Top pipe trim White 7054072 Bl...

Страница 23: ...ck supply Renew or reset fuse or circuit breaker If it fails again consult a qualified electrician 1 2 1 Power cut Check other appliances and if necessary contact local Electricity Supply Co 1 2 2 Have unit checked Ring Customer Service 1 3 1 The thermal cut out safety device has operated Have the unit checked by a suitably qualified service engineer or contact Customer Service 2 1 1 Alter the tem...

Страница 24: ...n fitting a new PRD follow the commissioning procedure It is advised all electrical maintenance repairs to the shower should be carried out by a suitably qualified person In the unlikely event of a fault occurring please contact Triton Customer Service DO NOT remove the shower from the installation ...

Страница 25: ...23 ...

Страница 26: ...24 ...

Страница 27: ...25 ...

Страница 28: ...ously and expects customers to treat all staff members with respect Should any employee feel threatened or receive abuse either verbally or physically Triton reserves the right to withhold service and will support the employee with a legal prosecution Replacement Parts Policy Availability It is the policy of the manufacturer to maintain parts availability for the duration of production and a perio...

Отзывы: