WATER REQUIREMENTS
Note:
if the recommended running pressure and
flow is not available there will be a noticeable
reduction in flow from the showerhead.
• If it is intended to operate the shower at
pressures above the maximum or below the
minimum stated, contact Customer Service
for advice.
Fig.5
shows a typical system layout.
DO NOT
use jointing compounds on any
pipe fittings for the installation.
Isolating
stopvalve
Mains
water
supply
Shower
unit
Switch may
be wall
mounted
in accordance
with IEE regs.
Mains electric supply (via double pole switch)
Double
pole
isolating
switch
Separate permanently
connected supply
from consumer unit
Diagrammatic view (not to scale)
The installation must be in accordance with Water Regulations/Bylaws.
Supply Source ............................................ Mains pressure cold water only
Minimum running pressure
100kPa (1 bar) at 8 litres per minute*
and flow at the shower inlet*
Maximum static pressure ........................... 1000 kPa (10 bar)
Maximum inlet temperature ...................... 28°C
Minimum inlet temperature ....................... 2°C
.....................