18
CONNECTING THE PCB CABLE
& REPLACING THE COVER
Important:
Before fi nally fi tting the cover, the
following steps must be taken:
a. Check all plumbing connections are
watertight.
b. Check terminal block screws are fully
tightened.
c. Make sure the pipe and cable entering
the unit do not prevent the cover locating
correctly onto the backplate.
• See
(fig.16 & 17 on page 16)
for the
correct positions of the temperature spindle
and temperature knob.
• Attached to the display PCB, inside the cover,
is a 10-way ribbon cable. The ribbon cable
connector must be plugged into the socket
located at the right of the power PCB situated
inside the unit
(fig.20)
.
• The cable connector can only be fitted into
the socket in one way. The ribbon cable has
a coloured edge which is lowermost when
correctly fitted to the socket.
NOTE:
The ribbon cable is preformed to fold flat
when the cover is fitted.
• Guide the cover into position so that the knob
spindle locates correctly (minor adjustment
may be necessary to align the knob and
spindle). Should any difficulty arise, re check
the points above.
• While applying slight pressure to the cover,
secure in position with the retaining screws.
• Turn the electric supply back on at the
isolating switch. The ‘
Power
’ indicator will
light.
• Water will
NOT
flow until the
Start/Stop
button is pressed.
• However, it is recommended that the water
and electric supplies to the shower are turned
off while the riser rail kit is being installed.
• The flexible hose can be left attached to the
shower outlet. Make sure the supplied sealing
washer is fitted.
CONNECTING THE PCB CABLE & REPLACING THE COVER
Coloured
edge
Fig.20
IMPORTANT - CLEANING
It is recommended that all products
are cleaned using warm, soapy water.
DO NOT
use abrasive or aggressive
chemical cleaning products as this may
affect the product surface fi nish and
invalidate your guarantee.