17
COMMISSIONING
•
IMPORTANT:
The Temperature control
MUST
now be turned fully
clockwise
to
the ‘minimum flow’ position, as shown in
(fig.18) - Failure to do this could make
the PRD operate.
• Turn on the water supply to the shower at the
isolating stopvalve. Switch on the electricity
supply to the shower at the isolating switch.
• Wait until water starts to flow from the
flexible hose.
• Slowly rotate the temperature control fully
anticlockwise to the maximum flow position,
as shown in
(fig.19)
.
• It will take about thirty seconds for a smooth
flow of water to be obtained while air and
any debris is being flushed from the shower.
When a smooth flow of water is obtained,
turn the temperature control from minimum
flow to maximum flow and back again several
times to release any trapped air from within
the unit.
• Once the flushing out has been completed,
switch off the electricity to the shower at the
isolating switch. The water will cease to flow.
• Unscrew the top and bottom retaining screws
again, and lift the cover from the backplate.
Fig.18
Temperature control
at ‘minimum fl ow’ position
Fig.19
Temperature control
at ‘maximum fl ow’ position