Manual LCO EXC3/ADV3 OTD | 03-2020 | 1.2 | en
Power-up fading
c
53 / 63
Power-up Fading (only EXC3)
Description
The power-up fading function offers the opportunity to realize a soft start. The soft start will be applied when the mains supply is
switched on and during operation with switchDIM. The function is programmed as a DALI fade time in the range from 0.7 to 16
seconds and dims in the selected time from 0 percent to the power-on level.
By factory default power-up fading is not active (0 seconds).
Commissioning
Activating and adjusting Power-up Fading via masterCONFIGURATOR
The Power-up Fading function can be activated and adjusted via the masterCONFIGURATOR.
Further information can be found in the masterCONFIGURATOR manual (see
http://www.tridonic.com/com/en/download/Manual_masterConfigurator_en.pdf
...