Description
In the outdoor lighting and street lighting sector, it often makes sense to dim the lighting level during the night hours in order to save
energy. The
function is a tool that makes this easy to do.
chronoSTEP V2
The LED Driver automatically measures the switch-on and switch-off times of the lighting installation over the past three days. The
switch-on and switch-off times are typically the times at which the sun sets and rises. The midpoint of these two reference points is
the time referred to as Virtual Midnight. To allow immediate operation in the first night, it is possible to program the Virtual Midnight
manually.
The overall time between switch-ON and switch-OFF is called On-Time.
Overall there are 8 profiles, 5 are predefined by factory and 3 can be programmed by the customer using the mains programming
protocol U6Me2.
Profiles:
Default profile: Profile 1
Profile 0 - Light output is set to 100 %, chronoSTEP V2 deactivated
Profile 1 - Factory default if chronoSTEP V2 mode is activated
Profile 1-4 predefined
Profile 5-8 user defined and programmable
...