Designers Manual
Advanced Energy CoolX600 Series
TTaabbllee 66‑‑55.. CoolMod signal connector pin assignments
PPiinn
JJ110000
xx
AAssssiiggnnm
meenntt
1
Common
2
PG
x
3
Common
4
EN
x
5
I
trim
x
6
V
trim
x
TTaabbllee 66‑‑66.. CoolMod output signal connector types
C
Coonnnneeccttoorr
C
Coonnnneeccttoorr TTyyppee
J1001-J1004 connectors
6-way Molex 87833-0831
J1001-J1004 mating connectors
Locking Molex 51110-0660, non-locking
Molex 51110-0650, or locking and
polarizing Molex 51110-0650
Crimp terminal: Molex p/n 50394
IIN
NSSTTAALLLLIIN
NG
G TTH
HEE U
UN
NIITT
To Install CoolMod Modules
1. Plug one module into the CoolPac chassis.
2. Secure the module to the base of the chassis with two mounting screws.
3. Plug in and secure the rest of the modules.
4. Fit the plastic retainer bar across the top of the modules.
The plastic retainer bar improves the ruggedness of the CoolX unit and
increases its resistance to shock and vibrations.
SSEER
RIIEESS C
CO
ON
NN
NEEC
CTTIIO
ON
N O
OFF M
MO
OD
DU
ULLEE O
OU
UTTPPU
UTTSS
You can connect modules in series, using series links, to increase output voltage.
Advanced Energy
®
CoolX
®
600 Modular Power Supply
57010208-00B
Installation, Setup, and Operation
6‑9