Designers Manual
Advanced Energy CoolX600 Series
TTaabbllee 33‑‑77.. Standard module protective limits specifications
PPaarraam
meetteerr
VVaalluuee
TTyyppee
C
Cm
mAA
C
Cm
mBB
C
Cm
mC
C
C
Cm
mD
D
Current limit (brick-
wall limit,
autorecovery)
Minimum
23.1 A
16.5 A
9.2 A
4.6 A
Nominal/
Typical
25.2 A
18.1 A
9.7 A
5 A
Maximum 27.3 A
19.5 A
10.8 A
5.4 A
Short circuit current
(RMS)
Maximum 4.2 A
3 A
1.7 A
0.9 A
Power limit (voltage
foldback, autorecovery)
Minimum
115 W
198 W
220 W
220 W
Nominal/
Typical
130 W
220.5 W 232 W
230 W
Maximum 137 W
234 W
260 W
260 W
Overvoltage protection
(shutdown,
autorecovery)
Minimum
6.8 V
17 V
32 V
60 V
Nominal/
Typical
8 V
19.8 V
35 V
62.2 V
Maximum 9 V
21 V
37 V
66 V
Sense lead protection
(shutdown,
autorecovery)
Maximum 3.1 V
3.1 V
3.1 V
3.1 V
In
Figure 3
‑
2
, t1 is the hiccup timing (on-time) and t2 is the hiccup timing (off-time).
Table 3
‑
8
contains t1 and t2 values for each type of CoolMod module.
FFiigguurree 33‑‑22..
Module hiccup characteristics
TTaabbllee 33‑‑88.. Standard module hiccup characteristics specifications
PPaarraam
meetteerr
VVaalluuee
TTyyppee
C
Cm
mAA
C
Cm
mBB
C
Cm
mC
C
C
Cm
mD
D
Hiccup timing (on-
time)
Minimum
1 ms
1 ms
1 ms
1 ms
Nominal/
Typical
5 ms
5 ms
5 ms
5 ms
Advanced Energy
®
CoolX
®
600 Modular Power Supply
57010208-00B
Specifications