Installation Considerations
The CoolX unit can be mounted on any of its three surfaces using standard M4
screws. The chassis comes with four mounting points on the base and two mounting
points on each side. Maximum allowable torque for mounting screws is 2 Nm
(17.7 in-lb) and maximum allowable penetration depth is 2 mm (0.08″). DIN-rail
mounting is also possible using the Excelsys DIN-rail mounting bracket.
Avoid excessive bending of output power cables after they are connected to the
modules. For high current outputs, use cable ties to support heavy cables and
minimize mechanical stress on output terminals. Be careful not to short out to
neighboring output terminals. The maximum torque allowed on output connectors is
2 Nm (17.7 in-lb).
Mechanical Information