Designers Manual
Advanced Energy CoolX600 Series
TTaabbllee 33‑‑22.. Electrical specifications (Continued)
D
Deessccrriippttiioonn
SSppeecciiffiiccaattiioonn
•
“Bulk Module Specifications”
on page 3
‑
9
•
“Dual Module Specifications”
on page 3
‑
13
•
“Wide-trim Module Specifications”
on page 3
‑
16
Auxiliary Output
Nominal output
voltage
Aux Voltage Option A
Aux Voltage Option B
Nominal 12 V
Minimum 11.76 V
Maximum 12.24 V
Nominal 5 V
Minimum 4.75 V
Maximum 5.25 V
Load regulation
± 2%
Line regulation
± 0.5% (for ± 10% change from nominal line)
Output current
(maximum)
Aux Voltage Option A
Aux Voltage Option B
1.96 A
4.7 A
Output capacitive
load (maximum)
1,000 μF
Output
overcurrent
protection
110% to 140% (hiccup condition)
Short circuit
protection
Yes, autorecovery
Leakage Currents
(at mains voltage 264 VAC/60 Hz)
Type
AC leakage current (input to earth
ground)
Touch current
Normal condition 248 μA
4.7 μA
Single fault
condition
393 μA
247 μA
Operational Limits
Extended AC
operating range
300 VAC for a maximum of 5 secs
Electrical
efficiency
> 93% at 230 VAC, 600 W with three CmC modules
Power factor
> 0.92 at full rated power, nominal line conditions
Undervoltage
lockout
68 VAC through 84 VAC, shutdown
1
Operating off > 63 Hz puts the unit outside the unit safety ratings and approvals. Contact AE Global
Services before operating the unit off > 63 Hz.
2
Operation with DC inputs is not within unit safety ratings and approvals. Contact AE Global Services
before operating the unit with DC inputs.
Advanced Energy
®
CoolX
®
600 Modular Power Supply
57010208-00B
Specifications
3‑3