OTP condition persists for a further 2 sec, the CoolX unit will shut down. The unit
will auto-recover when temperatures reach the normal operating level.
☞
Important
On dual modules, the
OVERTEMPERATURE PROTECTION
signal is latch-
off; the signal will not auto-recover. The unit will require a reset (removal of
power for two minutes) to recover.
Shut down from the
OVERTEMPERATURE PROTECTION
signal depends on the
environment. This signal can be used to turn on an external fan or to shed loads, both
of which would reduce the temperature rise in the power supply.
☞
Important
The maximum collector voltage is 5 V, and the maximum collector current is
12 mA.
Figure 5
‑
2
and
Table 5
‑
2
provide recommendations for driving logic level circuits
with open collector signal outputs.
M
MO
OD
DU
ULLEE SSIIG
GN
NAALLSS
Each module has the following discrete controls:
•
“Module Enable/Inhibit”
•
“CoolMod Power Good Signal”
Module Enable/Inhibit
You can enable or inhibit each module by applying a logic level signal to the enable
input on output signal connector (J1001-J1004) pin 4 (positive) and pin 1 or pin 3
(negative). The input has a 1 kΩ series resistor and a 100 nF filtering capacitor to
filter noise on this signal. The enable and inhibit feature on dual modules works
differently; see
“Dual Module Enable/Inhibit”
on page 5
‑
6 for more information
and for the dual module enable/inhibit wiring diagram.
10k
10 nF
Comms
Board
Microcontroller
Module
Pin 4
Enable
Enable return
Pin 1 or
Pin 3
FFiigguurree 55‑‑33..
CoolMod enable/inhibit wiring diagram
There is a maximum 15 ms turn-on delay after application of the signal. When there
is no connection, pin 4 is high (5 V) and the module is enabled.
Advanced Energy
®
CoolX
®
600 Modular Power Supply
57010208-00B
Communication Controls
5‑4