Designers Manual
Advanced Energy CoolX600 Series
Rules for Safe Installation and Operation
Please note the following rules:
• Install the CoolX unit indoors. The CoolX unit is designed for indoor use.
• Install the CoolX unit so that it is only accessible to service engineers.
• Do not unplug CoolMod modules while input power is applied to the CoolPac
chassis. The modules are not designed for hot-plug insertion.
• Ensure that input and output screw terminals are torqued to 2 Nm (17.7 in-lb)
before applying power to the CoolX unit.
• Arrange positive and negative power cables as a twisted pair to minimize
inductive loops.
• Wait 4 minutes after shutting off power before inserting or removing modules.
• Use properly sized wires to avoid overheating and excessive voltage drop.
• Take appropriate precautions when touching the CoolX unit after it has been
operating for a period of time. Due to the conduction cooling methods to the
chassis, the chassis will remain hot for some time after power has been
removed. Exactly how long the chassis remains hot depends on the system
incorporating the CoolX unit.
• Completely disconnect the installation from power before working on the unit.
The unit uses double pole/neutral fusing. If the unit is not completely
disconnected from power, parts might remain live even if one of the two mains
fuses has blown.
IIN
NTTEER
RPPR
REETTIIN
NG
G PPR
RO
OD
DU
UC
CTT LLAABBEELLSS
The following labels might appear on your unit:
or
CE label
Complies with applicable European
directives.
Hazardous voltage
Voltage > 30 V
RMS
, 42.4 V peak, or
60 VDC
Hot surface
Advanced Energy
®
CoolX
®
600 Modular Power Supply
57010208-00B
Safety and Product Compliance Guidelines