Designers Manual
Advanced Energy CoolX600 Series
TTaabbllee 33‑‑1155.. Bulk module regulation specifications (Continued)
PPaarraam
meetteerr
VVaalluuee TTyyppee
C
Cm
mEE
C
Cm
mFF
Line regulation (85 VAC to
264 VAC)
Nominal/
Typical
50 mV
50 mV
Maximum
120 mV
120 mV
All bulk modules have a temperature regulation coefficient of 0.02%°C.
TTaabbllee 33‑‑1166.. Bulk module protective limits specifications
PPaarraam
meetteerr
VVaalluuee TTyyppee
C
Cm
mEE
C
Cm
mFF
Current limit (hiccup,
autorecovery)
Minimum
27 A
13.5 A
Nominal/Typical 29 A
14 A
Maximum
30 A
15 A
Short circuit current limit
(measured over 5 hiccup cycles)
Maximum
5 A
2.5 A
Power limit (hiccup,
autorecovery)
Minimum
615 W
615 W
Nominal/Typical 695 W
670 W
Maximum
755 W
755 W
Overvoltage protection
(shutdown, autorecovery)
Minimum
29 V
45.5 V
Nominal/Typical 30.5 V
59 V
Maximum
31.5 V
62 V
Sense lead protection
(shutdown, autorecovery)
Maximum
7 V
7 V
In
Figure 3
‑
2
on page 3
‑
6, t1 is the hiccup timing (on-time) and t2 is the hiccup
timing (off-time).
Table 3
‑
17
contains t1 and t2 values for each type of bulk module.
TTaabbllee 33‑‑1177.. Bulk module hiccup characteristics specifications
PPaarraam
meetteerr
VVaalluuee TTyyppee
C
Cm
mEE
C
Cm
mFF
Hiccup timing (on-time)
Minimum
1 ms
1 ms
Nominal/Typical 10 ms
10 ms
Maximum
200 ms
200 ms
Hiccup timing (off-time)
Minimum
500 ms
500 ms
Nominal/Typical 1000 ms
1000 ms
Maximum
7000 ms
7000 ms
Short circuit hiccup level
Minimum
27 A
13.5 A
Nominal/Typical 29 A
14 A
Advanced Energy
®
CoolX
®
600 Modular Power Supply
57010208-00B
Specifications