Installation
(for qualified installers only)
3 7
© Travis Industries
4080207
100-01185_000
Facing Detail – Facing Over 1” Thick (Brick)
WARNING
:
Any facing that extends in front of the faceplate on the sides or top must be non-
combustible.
NOTE
:
A 3/8” gap is required above the face for face installation.
Top View
NOTE: Make sure to leave a 1/8" gap
around the sides of the face and 3/8"
above (for face installation).
AA
Fireplace
Face
Drywall
Framing
AAAAA
Non-combustible facing material (brick, stone,
marble, tile) - required if the facing extends in
front of the face on the sides or top.
3/8"
The facing is brought up
to the wall trim.
The side facing should be spaced 1/8"
from the face (3/8” from the side of the
fireplace).
Wall Trim
Side View
A
A
Fireplace
AAAA
AAAA
NOTE: Bring the facing up to the
base of the fireplace.
In this example brick is used.
1/8"
3-d View
NOTE: When installed, there must be a minimum 1/8” gap
between the face and facing.
1/8"