2 2
Installation
(for qualified installers only)
© Travis Industries
4080207
100-01185_000
Wall Switch or Thermostat Installation
Wiring Diagram (Millivolt System)
Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. The switch must
be installed by a qualified installer.
Caution
: Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Orange
White
Piezo Igniter
Thermopile
Red
AA
AA
Thermocouple
Copper Co-Axial
Wire
Red
Spark Electrode
Pilot Hood
On/Off Switch (on fireplace)
Optional Wall Switch,
Thermostat, or
Remote Control
Brown
Installation
1.
Attach the included wire to the gas control valve.
Attach the two wires to the top and
bottom posts on the gas control
valve (orientation does not matter).
2.
Determine a location for the wall switch or thermostat (maximum 25' long). Route the wire through the
grommet on the right side of the fireplace (next to the electrical junction box).
3.
If using a thermostat, attach it following the manufacturer’s instructions. If using a wall switch, attach
following the directions below.
N O T E
: Set the on/off switch on the appliance to "OFF" to control the appliance with the wall switch or thermostat.
a
Carefully pack the wires into the
junction box. Attach the switch
to the junction box. Attach the
switchplate to the switch.
b
Standard
Screwdriver
From
Appliance
Insert the wire
through the back of
the mounted
junction box (your
junction box may
look different).
Expose 1/2" of
each wire. Secure
the wires to the
posts on the side of
the on/off switch
(orientation does
not matter).