Installation
(for qualified installers only)
© Travis Industries
4080207
100-01185_000
Approved Vent
•
Rear vent configurations use 8" diameter Simpson Dura-Vent Model GS or Pro vent.
•
Top vent configurations use 8" or 6-5/8" diameter Simpson Dura-Vent Model GS or Pro vent. If using
6-5/8" diameter vent, attach the 8" to 6-5/8" reducer (Travis part # 98900165) directly to the fireplace
(see the illustration below).
•
Installation instructions for Simpson Dura-Vent may be found at www.duravent.com
6-5/8" Diameter Vent
(minimum 12" vertical rise)
Reducer - # 98900165
Vent Installation
•
Slide the vent sections together and turn 1/4 turn until the sections lock in place.
•
Screws are not required to secure the vent. However, three screws may be used to secure vent
sections together if desired.
•
High temperature sealant is recommended at the appliance starter section connection (use high-
temperature silicone or Mill-Pac®).
•
If disassembly is required, at time of re-assembly check to see if the vent creates a tight fit. If it does
not, apply high temperature sealant to the joints of the affected sections.
•
Horizontal sections require a 1/4" rise every 12" of travel
•
Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)