Installation
(for qualified installers only)
2 3
© Travis Industries
4080207
100-01185_000
Vent Requirements
•
The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it's own separate vent system.
•
In addition to the requirements listed here, follow the requirements provided with the vent.
•
A firestop is required whenever the vent penetrates a wall, floor, or ceiling (passes through framing
members). Use the included firestop. It incorporates a 3" clearance above, 1" clearance below and to
the sides of the vent.
•
Always use the high-wind termination.
Vent Clearances
•
The vent must maintain the required clearance to combustible materials to prevent a fire. Do not fill air
spaces with insulation.
Sides
1"
Above
3"
Below Horizontal or 45
°
Section
1"
Use a firestop when
passing through any
wall (WARNING: some
firestops provide a 1"
clearance above the
vent -- 3" is required for
this heater).
Min. 3" Clearance
Above the Vent
AA
AA
AA
AA
Min. 1" Clearance to
the side of vent
AAAAA
1" Clearance to the sides
after the first firestop.
AA
AA
Use a firestop whenever
passing through a
ceiling, enclosure or
floor penetration.
Altitude Considerations
•
This heater has been tested at altitudes ranging from sea level to 6,000 feet. In this testing we have found that
the heater, with its standard orifice, burns correctly with just an air shutter adjustment.
•
Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.
Consult your dealer or installer if you suspect an improperly adjusted air shutter.