RTAF-SVX001A-EN
7
Model Number Descriptions
Unit Model Number
Digits 1, 2 — Unit Model
RT =
Rotary Chiller
Digit 3 — Unit Type
A
=
Air-cooled
Digit 4 — Development
Sequence
F
=
Development Sequence
Digits 5-7 — Nominal Capacity
115 =
115 Nominal Tons
130 =
130 Nominal Tons
150 =
150 Nominal Tons
170 =
170 Nominal Tons
180 =
180 Nominal Tons
200 =
200 Nominal Tons
215 =
215 Nominal Tons
Digit 8— Unit Voltage
C
=
380/60/3
D
=
400/50/3
E
=
460/60/3
Digit 9 — Manufacturing
Location
U
=
Trane Commercial Systems,
Pueblo, CO USA
Digits 10, 11— Design Sequence
XX =
Factory assigned
Digit 12 — Unit Efficiency
H
=
High Efficiency
Digit 13— Unit Sound Package
X
=
Standard Noise
Digit 14 — Agency Listing
U
=
UL/CUL Listing
Digit 15 — Pressure Vessel Code
A
=
ASME Pressure Vessel Code
C
=
CRN or Canadian Equivalent
Pressure Vessel Code
D
=
Australia Pressure Vessel Code
Digit 16 — Factory Charge
1
=
Refrigerant Charge R-513A
2
=
Refrigerant Charge R-134a
3
=
Nitrogen Charge
(R-513A Field Supplied)
4
=
Nitrogen Charge
(R-134a Field Supplied)
Digit 17 — Evaporator
Application
N
=
Standard Cooling
(above 40°F/5.5°C)
P
=
Low Temp Process Cooling
(below 40°F/5.5°C)
C
=
Ice Making
Digit 18 — Evaporator
Configuration
2
=
2-pass Evaporator
T
=
2-pass Evaporator
with Turbulators
Digit 19 — Evaporator Fluid
Type
1
=
Water
2
=
Calcium Chloride
3
=
Ethylene Glycol
4
=
Propylene Glycol
5
=
Methanol
Digit 20 — Water Connection
X
=
Grooved Pipe Connection
W
=
Grooved Pipe + Flange
Digit 21 — Flow Switch
1
=
Factory Installed - Other Fluid
15 cm/s
2
=
Factory Installed - Water
35 cm/s
3
=
Factory Installed - Water
45 cm/s
Digit 22 — Insulation
N
=
Factory Insulation
All Cold Parts 0.75”
Digit 23 — Unit Application
X
=
Standard Ambient
(14 to 115°F/-10 to 46°C)
L
=
Low Ambient
(-4 to 115°F/-20 to 46°C
H
=
High Ambient
(14 to 130°F/-10 to 54.4°C)
W
=
Wide Ambient
(-4 to 130°F/-20 to 54.4°C)
Digit 24 — Condenser Fin
Options
N
=
Aluminum Microchannel
Digit 25 — Fan Type
C
=
Variable Speed Fans
Digit 26 — Oil Cooler
C
=
Oil Cooler
Digit 27 — Compressor Starter
V
=
Variable Speed Compressors
Digit 28 — Incoming Power Line
Connection
1
=
Single Point Power Connection
Digit 29 — Power Line
Connection Type
X
=
Terminal Block
C
=
Circuit Breaker
H
=
Circuit Breaker with High Fault
Rated Control Panel
Digit 30— Short Circuit Current
Rating
A
=
Default Amp Short Circuit Rating
B
=
High Amp Short Circuit Rating
Digit 31 — Electrical
Accessories
X
=
No Convenience Outlet
P
=
15A 115V Convenience Outlet
Digit 32 — Remote
Communication Options
X
=
None
B
=
BACnet
®
Interface
M
=
Modbus™ Interface
L
=
LonTalk
®
Interface
Digit 33 — Hard Wire
Communication
X
=
None
A
=
Hard Wired Bundle - All
B
=
Remote Leaving Water Temp
Setpoint
C
=
Remote Leaving Temp and
Demand Limit Setpoints
D
=
Programmable Relay
E
=
Programmable Relay and
Leaving Water and Demand
Limit Setpoint
F
=
Percent Capacity
G
=
Percent Capacity and Leaving
Water and Demand Limit
Setpoint
H
=
Percent Capacity and
Programmable Relay
Digit 34 — Energy Meter
X
=
N-one
Digit 35 — Smart Flow Control
X
=
None
Digit 36 — Structural Options
A
=
Standard Unit Structure
Digit 37 — Appearance Options
X
=
No Appearance Options
Digit 38 — Unit Isolation
X
=
None
1
=
Elastomeric Isolators
Digit 39 — Shipping Package
X
=
No Shipping Package
A
=
Containerization Package
T
=
Shipped with Tarp Covering
Full Unit
Digits 40-42
XXX=
Reserved for future use
Digit 43 — Special Requirement
0
=
None
S
=
Special Requirement