Tradedor TD77DM & TD77SEL Installation Guide
Wiring As Follows:
Receiver Box Green 6 Block Terminal
(fig. 12.5)
:
L0
– Up wire from switch
L2
– Down wire from switch
L1
– Common wire for the supply to the switch
L1
– L3 Link wire between terminals
Rocker Switch
(fig. 12.2)
:
4
– Up wire
3
– Down wire from rocker switch
5
– Common wire for the supply to the switch
5
– 2 Link wire between terminals
To open rocker switch remove screws
Key Switch
(fig. 12.4)
:
Right Block 13
– Up wire
Left Block 14
– Down wire
Right Block 14
– Common wire for the supply to
the switch
Left Block 13
– Right Block 14 Link wire between
terminals
To open key switch remove screw then turn key
a quarter turn.
fig.12.5
fig.12.4
Hard Wired Rocker / Key Switch
(SAFETY EDGE, TYPE 1)
Fixing Options
Below Lintel Fixing:
Cut guide runners to measured height less 310 mm.
Limited Opening Fixing:
Measure from floor to highest point, deduct 310 mm and cut guide runners to size.
Behind Lintel Fixing:
Cut guide runners to measured height.