Printed in the Federal Republic of Germany
TR-Electronic GmbH 2014, All Rights Reserved
05/04/2018
TR - ELA - BA - DGB - 0023 - 06
Page 149 of 183
7.4.3.26 Attribute 50, Operating Time
Operating Time
contains the counted operating time of the measuring system in
0.1 hours.
UDINT, read only
Operating Time
Byte 0
Byte 1
Byte 2
Byte 3
2
7
up to 2
0
2
15
up to 2
8
2
23
up to 2
16
2
31
up to 2
24
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x32
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #50
7.4.3.27 Attribute 51, Offset Value
Offset Value
displays the offset value relating to the physically zero point.
According to the number of configured magnets at Attribute 110, Number of Magnets
a new instance is produced for each installed magnet.
Attribute 51, Offset Value = Attribute 19, Preset Value - Attribute 10, Position Value Signed
DINT, read only
Offset value
Byte 0
Byte 1
Byte 2
Byte 3
2
7
up to 2
0
2
15
up to 2
8
2
23
up to 2
16
2
31
up to 2
24
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01...0x03
0x30
0x33
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Instance #2
Instance #3
Logical Type
=Attr.-ID
Attr.-ID #51