Printed in the Federal Republic of Germany
TR-Electronic GmbH 2014, All Rights Reserved
05/04/2018
TR - ELA - BA - DGB - 0023 - 06
Page 147 of 183
7.4.3.22 Attribute 46, Alarm Flag
The
Alarm Flag
displays if a position error of at least one magnet or an EEPROM
error has occurred.
BOOL
Access
Value
Description
Get
0
no error occurred
1
error occurred
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x2E
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #46
7.4.3.23 Attribute 47, Warnings
The
Warnings
attribute indicates that tolerance for certain internal parameters of the
device have been exceeded. In contrast to alarms, warnings do not imply incorrect
position values. All warnings are cleared if the tolerances are again within normal
parameters. According to the number of configured magnets at Attribute 110, Number
of Magnets a new instance is produced for each installed magnet.
WORD, read only
Bit
Description
FALSE (0)
TRUE (1)
0
…5 Reserved
-
-
6
Minimum velocity fall below
OK
fall below
7
Maximum velocity exceeded
OK
exceeded
8…9 Reserved
-
-
10
Position limits exceeded
OK
exceeded
11…12 Reserved
Always 0
13
Minimum temperature fall below
OK
fall below
14
Maximum temperature exceeded
OK
exceeded
15
Reserved
-
-
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01...0x03
0x30
0x2F
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Instance #2
Instance #3
Logical Type
=Attr.-ID
Attr.-ID #47