Printed in the Federal Republic of Germany
TR-Electronic GmbH 2014, All Rights Reserved
05/04/2018
TR - ELA - BA - DGB - 0023 - 06
Page 145 of 183
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01...0x03
0x30
0x1C
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Instance #2
Instance #3
Logical Type
=Attr.-ID
Attr.-ID #28
To save this attribute permanently the attribute 112
Accept Parameter
or service
code 0x16
save
must be executed.
7.4.3.18 Attribute 42, Physical Resolution Span
Physical Resolution Span
displays the smallest physical possible resolution.
UDINT, read only, default 1000
smallest physical resolution in nm
Byte 0
Byte 1
Byte 2
Byte 3
2
7
up to 2
0
2
15
up to 2
8
2
23
up to 2
16
2
31
up to 2
24
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x2A
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #42
7.4.3.19 Attribute 43, Number of Spans
Number of Spans
displays the physical possible measuring range. At linear
measuring systems firmly set to 1.
UINT, read only
Physical measuring range
Byte 0
Byte 1
Byte 2
Byte 3
2
7
up to 2
0
2
15
up to 2
8
2
23
up to 2
16
2
31
up to 2
24
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x2B
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #43