7.4.3.5 Attribute 12, Direction Counting Toggle
Direction Counting Toggle
sets the counting direction of the measuring
system. The setting is carried out for all installed magnets.
BOOL
Access Value Description
Default
Set/Get
0
Position rising at rod end
X
1
Position falling at rod end
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x0C
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #12
To save this attribute permanently the attribute 112
Accept Parameter
or service
code 0x16
save
must be executed.
7.4.3.6 Attribute 15, Position Format
The
Position Format
defines the unit for the position output (Attribute 10, Position
Value Signed). The unit is indicated internally in nanometer [nm]. Together with
Attribute 18, Position Measuring Increment, internally the corresponding resolution
(Attribute 16, Measuring Units per Span) is calculated:
Resolution [nm] = Unit [nm] * Position Measuring Increment [nm]
Example with the given default values of the attributes
Resolution [nm] = 1000 nm * 1 nm = 1000 nm per step
This value is saved in Attribute 16, Measuring Units per Span and applies to all
installed magnets.
ENGUNIT
Value
Unit
Value in nm
Default
0x2202
[cm]
10 000 000
0x2203
[mm]
1000 000
0x2204
[μm]
1000
X
0x2205
[nm]
1
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x0F
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #15
To save this attribute permanently the attribute 112
Accept Parameter
or service
code 0x16
save