7.4.3.3 Attribute 10, Position Value Signed
Position Value Signed
returns the position value as a binary coded value with
sign. According to the number of configured magnets at Attribute 110, Number of
Magnets a new instance is produced for each installed magnet.
DINT, read only
Position Value
Byte 0
Byte 1
Byte 2
Byte 3
2
7
up to 2
0
2
15
up to 2
8
2
23
up to 2
16
2
31
up to 2
24
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01...0x03
0x30
0x0A
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Instance #2
Instance #3
Logical Type
=Attr.-ID
Attr.-ID #10
7.4.3.4 Attribute 11, Position Sensor Type
The
Position Sensor Type
returns the device type.
UINT, read only
Value
Definition
10 (0x000A)
Multi-Sensor Encoder Interface
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x0B
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #11