7.4.3.35 Attribute 111, Position Status
The
Position Status
reports whether all magnets are located within the
permissible measuring range. If the error "No magnet detected" is reported, either no
magnet is installed, the magnet is located in the damping zone or the number of
magnets configured does not agree with the real number. No analyzable measuring
signal can be output by the measuring system within the damping zone.
Data type
UDINT
Access
Get
Lower limit
0
Upper limit
1
Default
0
Value
Description
Default
0x00 00 00 00 No error
X
0x00 00 00 01 No magnet detected
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x6F
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #111
7.4.3.36 Attribute 112, Accept Parameter
Accept Parameter
complies to the service code 0x16 (Save Parameter) and saves
the measuring system parameter into the non-volatile memory (EEPROM).
With write access ≠ 0 all changed attributes of all instances are stored permanently
and the acceptance of changed values for the instance attributes is performed.
Data type
USINT
Access
Set / Get
Lower limit
0
Upper limit
255
Default
0
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x70
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #112