CANopen communication
Printed in the Federal Republic of Germany
©
TR-Electronic GmbH 2007, All Rights Reserved
05/16/2007
TR - EMO - BA - DGB - 0013 - 00
Page 229 of 260
4.2.4.6.21 Object 0x606C: Actual speed
Object code
VAR
Data type
INTEGER32
Attribute
ro
Default
-
Min
-
Max
-
PDO mapping
yes
Description
This object contains the current speed in speed units.
4.2.4.6.22 Object 0x6071: Target torque
Object code
VAR
Data type
INTEGER16
Attribute
rw
Default
0
Min
0
Max
10000
PDO mapping
yes
Description
This parameter contains the target torque.
Unit: Thousandths of rated torque (0x6076).
4.2.4.6.23 Object 0x6072: Maximum torque
Object code
VAR
Data type
UNSIGNED16
Attribute
rw
Default
1250
Min
0
Max
10000
PDO mapping
yes
Description
This object contains the maximum permissible torque of the motor.
Unit: Thousandths of rated torque.
The default value 1250 corresponds to 125 % of the rated torque (0x6076).