CANopen communication
©
TR-Electronic GmbH 2007, All Rights Reserved
Printed in the Federal Republic of Germany
Page 162 of 260
TR - EMO - BA - DGB - 0013 - 00
05/16/2007
Status
Condition
Description
Not Ready to switch on
ZSW = xxxx xxxx x0xx 0000
The drive is in the initialization phase.
Switch on disabled
ZSW = xxxx xxxx x1xx 0000
Drive initialization ended.
The output stage cannot be switched on.
Ready to switch on
ZSW = xxxx xxxx x01x 0001
The output stage can be switched on.
Drive parameters can be changed.
Switched on
ZSW = xxxx xxxx x01x 0011
Output stage switched on.
Operation enabled
ZSW = xxxx xxxx x01x 0111
The drive can be used in accordance with
the set operating mode:
Positioning ramp operating mode:
Target position can be accepted.
Speed ramp operating mode:
Drive accelerates to the
preset target speed.
Quick stop active
ZSW = xxxx xxxx x00x 0111
The drive performs a quick stop. If the
Quick Stop Option Code (Object 0x605A)
is 5, the drive then remains in this state.
Fault reaction active
ZSW = xxxx xxxx x0xx 1111
There is an error. The relevant
troubleshooting is carried out.
Fault
ZSW = xxxx xxxx x0xx 1000
Troubleshooting is complete.
Table 12: States