CANopen communication
Printed in the Federal Republic of Germany
©
TR-Electronic GmbH 2007, All Rights Reserved
05/16/2007
TR - EMO - BA - DGB - 0013 - 00
Page 189 of 260
4.2.4.4.4 Object 0x1004: Number of supported PDOs
This object is not implemented at present, but is required by certain controls in order to be able to read
the predefined PDOs.
Object code
RECORD
Description
This parameter specifies how many PDOs are supported in each transmission
direction.
Subindex 0: Number of PDOs
Data
type
UNSIGNED32
Attribute
ro
Default
0x00060006
Min
-
Max
-
PDO
mapping
-
Description
Contains the maximum number of PDOs in both transmission
directions.
Bit 0-15: PDOs sent by encoTRive (6)
Bit 16-31: PDOs received by encoTRive (6)
Subindex 1: Number of synchronous PDOs
Data
type
UNSIGNED32
Attribute
ro
Default
0x00060006
Min
-
Max
-
PDO
mapping
-
Description
Contains the maximum number of synchronous PDOs in
both transmission directions.
Bit 0-15: PDOs sent by encoTRive (6)
Bit 16-31: PDOs received by encoTRive (6)
Subindex 2: Number of asynchronous PDOs
Data
type
UNSIGNED32
Attribute
ro
Default
0x00060006
Min
-
Max
-
PDO
mapping
-
Description
Contains the maximum number of asynchronous PDOs in
both transmission directions.
Bit 0-15: PDOs sent by encoTRive (6)
Bit 16-31: PDOs received by encoTRive (6)