CANopen communication
©
TR-Electronic GmbH 2007, All Rights Reserved
Printed in the Federal Republic of Germany
Page 210 of 260
TR - EMO - BA - DGB - 0013 - 00
05/16/2007
4.2.4.5.2 Object 0x2E02: Temperature / Bus address / Baud rate
Object code
RECORD
Description
Temperature sensors and the DIP switches for Node ID and Baud Rate can be
read out with these parameters.
Subindex 0: Number of entries
Data
type
UNSIGNED8
Attribute
ro
Default
8
Min
-
Max
-
PDO
mapping
yes
Description
Number of following entries
Subindex 1: Self-test result
Data
type
UNSIGNED16
Attribute
ro
Default
0
Min
-
Max
-
PDO
mapping
yes
Description
Error code during execution of self-test after power supply
ON. If no error has occurred, the result is 0. Otherwise an
EMCY message is issued (see chapter "6.2 EMCY error
information" from page 253), and the drive is switched off.
Status word = "Not ready for operation".
Subindex 2: Temperature sensor 1
not present in MD025
Data
type
UNSIGNED16
Attribute
ro
Default
0
Min
-
Max
-
PDO
mapping
yes
Description
The sensor value specifies the temperature of the CPU
board in °C. If the sensor fails, the EMCY message "4280"
is issued (see chapter "6.2 EMCY error information" from
page 253), and the drive is switched off.