CANopen communication
Printed in the Federal Republic of Germany
©
TR-Electronic GmbH 2007, All Rights Reserved
05/16/2007
TR - EMO - BA - DGB - 0013 - 00
Page 211 of 260
Subindex 3: Temperature sensor 2
Data
type
UNSIGNED16
Attribute
ro
Default
0
Min
-
Max
-
PDO
mapping
yes
Description
The sensor value specifies the temperature of the power
board in °C. If the sensor fails, the EMCY message "4380"
is issued (see chapter "6.2 EMCY error information" from
page 253), and the drive is switched off.
Subindex 4: Address switch and baud rate
Data
type
UNSIGNED16
Attribute
ro
Default
0
Min
-
Max
-
PDO
mapping
yes
Description
Contains the actual value of the HEX switches for baud
rate and node address.
Byte n
= Node address
Byte n+1 = Baud rate
Subindex 6: Actual torque generating current limitation
Data
type
UNSIGNED16
Attribute
ro
Default
0
Min
-
Max
-
PDO
mapping
yes
Description
Unit: Rated motor current /1000
The roots of the square sum of object 6073 "Maximum
current" and object 2F02 "Idle current limitation" SubA
must not exceed the drive's physical current limitation.
The idle current is limited first of all, then the torque
generating current.
Subindex 7: Actual idle current limitation
Data
type
UNSIGNED16
Attribute
ro
Default
0
Min
-
Max
-
PDO
mapping
yes
Description
Unit: Rated motor current/1000.
For description see Subindex 6.