CANopen communication
©
TR-Electronic GmbH 2007, All Rights Reserved
Printed in the Federal Republic of Germany
Page 228 of 260
TR - EMO - BA - DGB - 0013 - 00
05/16/2007
4.2.4.6.18 Object 0x6068: Position window timeout
Object code
VAR
Data type
UNSIGNED16
Attribute
rw
Default
100
Min
0
Max
2
16
-1
PDO mapping
yes
Description
The parameter value specifies the minimum time in 1 ms steps for which the
actual position value must be present in the position window, before "Target
reached" is indicated in the status word.
4.2.4.6.19 Object 0x6069: Measured speed
Object code
VAR
Data type
INTEGER32
Attribute
ro
Default
-
Min
-
Max
-
PDO mapping
yes
Description
The parameter contains the speed value measured on the speed encoder in
speed increments.
4.2.4.6.20 Object 0x606B: Nominal speed
Object code
VAR
Data type
INTEGER32
Attribute
ro
Default
-
Min
-
Max
-
PDO mapping
yes
Description
This object contains the target speed in speed units, which results from the
control algorithm.