Printed in the Federal Republic of Germany
TR-Electronic GmbH 2011, All Rights Reserved
06/28/2017
TR - ECE - BA - DGB - 0084 - 05
Page 55 of 55
4.4 Position value
4.4.1 Position value
In the online state in the field
Position
the current measuring system position is
displayed.
With entering of a value into the field
Position
the measuring system can be
adjusted on the desired position value. The new position is set if the function
Data
write to device
is executed.
Origin Type
≤
desired position value
< programmed Total number of steps
4.4.2 Speed 1/Min
In the online state in the field
Speed 1/Min
the current measuring system speed in
min
-1
is displayed.
5 Causes of faults and remedies
Fault
Cause
Remedy
Position skips
of the measuring
system
Electrical faults
EMC
Perhaps isolated flanges and couplings made of plastic
help against electrical faults, as well as cables with twisted
pair wires for data and supply, see chapter Cable definition
on page 37.
Extreme axial and
radial load on the
shaft may result in a
scanning defect.
Couplings prevent mechanical stress on the shaft. If the
error still occurs despite these measures, the measuring
system must be replaced.