Parameterization via TRWinProg
TR-Electronic GmbH 2011, All Rights Reserved
Printed in the Federal Republic of Germany
Page 54 of 55
TR - ECE - BA - DGB - 0084 - 05
06/28/2017
4.3.4 For the speed output valid parameters
Start and final value in 1/Min:
With the parameters
start value in 1/Min
and
final value in 1/Min
the n-range can be defined within the speed limits of -6000 1/Min and +6000 1/Min.
Thereby the start value must be defined smaller than the final value.
Start and final value in µA:
With the parameters
start value in µA
and
final value in µA
it can be
defined the I-range within the maximum current values. Thereby the start value must
be defined smaller than the final value.
Example:
Figure 12: Definition of the active range (current / speed)
Legend
I
O
= actual measured output current mA
I
max
= maximal possible output current [mA]
I
SV
= programmed
start value
of the current
in µA
I
FV
= programmed
final value
of the current
in µA
n
= actual speed of the measuring system [1/Min] *
n
max
= maximal permissible speed of the measuring system [1/Min] *
n
SV
= programmed
start value
of the speed
in 1/Min
*
n
FV
= programmed
final value
of the speed
in 1/Min
*
* signed