Parameterization via TRWinProg
TR-Electronic GmbH 2011, All Rights Reserved
Printed in the Federal Republic of Germany
Page 52 of 55
TR - ECE - BA - DGB - 0084 - 05
06/28/2017
4.3 Analog output, current
4.3.1 Analog position or speed
With the parameter
Analog position or speed
the type of analog output is
defined.
Selection
Description
Unit
Default
Position
current value represents the position
Steps
X
Speed 1/Min
current value represents the speed
1/Min
4.3.2 Latch
The parameter
Latch
is for the transient saving of the output data.
Selection
Description
Default
Never
Latch function disabled
X
0=Locked
output data is frozen if the latch input is at low (U < 2 V)
1=Locked
output data is frozen if the latch input is at
high (U ≥ 8 V)