Printed in the Federal Republic of Germany
TR-Electronic GmbH 2011, All Rights Reserved
06/28/2017
TR - ECE - BA - DGB - 0084 - 05
Page 49 of 55
4.2 Analog output, voltage
4.2.1 Analog position or speed
With the parameter
Analog position or speed
the type of analog output is
defined.
Selection
Description
Unit
Default
Position
voltage value represents the position
Steps
X
Speed 1/Min
voltage value represents the speed
1/Min
4.2.2 Latch
The parameter
Latch
is for the transient saving of the output data.
Selection
Description
Default
Never
Latch function disabled
X
0=Locked
output data are frozen if the latch input is low (U < 2 V)
1=Locked
output data are frozen if the latch input is high (U ≥ 8 V)
4.2.3 Inverted
The parameter
Inverted
defines if the voltage output is inverted. That implies a
sign changing.
Selection
Description
Default
Not inverted
the voltage output is not inverted
X
inverted
the voltage output is inverted
not inverted,
inverted
Figure 8: Inverting of the voltage output