- 28 -
tousek
/ EN_ST-63_02 / 25. 03. 2020
Note: The factory settings of the single menu
points are marked with
in this manual.
The mechanical stops have to be placed so
that possibly existing safety contact edges
can not be triggered, as this would lead to
an error message.
status display
Diagnosis
Status display
for inputs as photocell, safety sensing edges, stop button, impulse switch ....
I
impulse button
P
pedestrian entry
C
CLOSE-button
S
STOP-button
O
OPEN-button
L
induction loop detector contact (ISD)
E
emergency mode switch
Pi
inner photocell
Po
outer photocell
Pb
back area photocell
delete position
Diagnosis
NO:
does not delete the end positions “gate closed”
and “gate open”
YES:
the determined end positions are beeing deleted.
Note: the end positions will be determined after new impulse.
factory setting
Diagnosis
NO:
no reset back to factory settings
YES:
reset back to factory settings
software version
Diagnosis
shows the software version on display
gate type:
S
swing gate /
F
folding gate
operator type:
X3TP
/
X4TP
serial number
Diagnosis
shows the serial number on display
protocol
Diagnosis
shows the protocol list on display:
all events that take place are protocolled in this list.
with the buttons
+
and
-
the single events can be seen:
Emergency mode not activated → normal operation
All inputs okay.
Status: not triggered
Status: triggered
Status: contact strip not connected or defect
Status: s. edge or photocell deactivated in menu
e.g.
Diagnosis
Connections and adjustments
Emergency mode not activated → normal operation
Impulse-, pedestrian- and CLOSE-buttons not triggered.
STOPP-button and inner photocell triggered.
Outer photocell not triggered.
Back area photocell deactivated in menu
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
IPCSOLE Pi Po Pb
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
IPCSOLE Pi Po Pb
- - o
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Softwareversion
V2.0.999 S X3TP
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Softwareversion
V2.0.999 F X4TP
e.g. swing gate with
SWING X3 TPspeed operator
e.g. folding gate with
SWING X4 LHTP operator
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
T -00 00:00:00.0
event
With
*
the protocol beginning
hence the end is shown
Type of event
Time since the last event:
DAYS HOURS : MINUTES : SECONDS
$
o
$