additional module
Peripherie
gate status display 1:
with the two potential-free signal contacts K1 and K2, the gate end positions (limits) can be
evaluated.
gate status display 2:
with the two potential-free signal contacts K1 and K2, the gate end positions (limits), the gate
movement as well as a gate stop outside of the end positions can be evaluated.
Additional module (optional)
•
turn off power supply before installing the additional module!
• The module „
evaluation of gate status“
has to be plugged to the
according slot/plug
(ZM)
of control board.
• Additionally the corresponding value has to be selected in menu point
„Additional module“
Additional module Gate status display
• with potential free signal contacts K1 (Kl. 90/91) and K2 (Kl. 92/93) the
gate staturs can be evaluated in two ways.
• Contact load:
24Va.c./d.c., max. 10W
Function
K1 K2
Gate status display
1
Gate in CLOSE-Position
1
0
Gate in OPEN-Position
0
1
2
Gate in CLOSE-Position
0
0
Gate opens or closes
0
1
Gate stopped or fault
(Gate not in end position)
1
0
Gate in OPEN-position
1
1
signal contacts: 0 = open, 1= closed
90 91 92 93
signal contacts
K1
K2
ZM
Z
ZM
ST 63