– 3 –
1. SPECIFICATIONS
1-1. Specifications
RAS-10JKVP-E/RAS-10JAVP-E, RAS-13JKVP-E/RAS-13JAVP-E
• The specifications may be subject to change without notice for purpose of improvement.
Indoor
RAS-10JKVP-E
RAS-13JKVP-E
Unit model
Outdoor
RAS-10JAVP-E
RAS-13JAVP-E
Current limited
—
—
Cooling capacity
(kW)
2.5
3.5
Cooling capacity range
(kW)
0.6–3.4
0.6–4.2
Heating capacity
(kW)
3.2
4.2
Heating capacity range
(kW)
0.6–6.2
0.6–6.6
Power supply
1Ph/50Hz/220–240 V, 1PH/60Hz/220 V
Operation mode
Cooling
Heating
Cooling
Heating
Running current
(A)
0.15
0.15
0.15
0.15
Power consumption
(W)
30
30
30
30
Indoor
Power factor
(%)
87
87
87
87
Operation mode
Cooling
Heating
Cooling
Heating
Running current
(A)
2.58/2.46/2.35
3.44/3.28/3.14
4.40/4.20/4.02
5.07/4.84/4.63
Power consumption
(W)
540
720
920
1060
Power factor
(%)
95
95
95
95
Electric
characteristics
Outdoor
Starting current
(A)
3.59/3.43/3.29
5.22/4.99/4.78
COP
(Cooling/Heating)
4.39/4.27
3.68/3.85
High
(Cooling/Heating) (dB•A)
42/43
43/44
Medium (Cooling/Heating) (dB•A)
33/34
34/35
Indoor
Low
(Cooling/Heating) (dB•A)
25/25
26/26
Operating
noise
Outdoor
(Cooling/Heating) (dB•A)
45/47
48/50
Unit model
AS-10JKVP-E
RAS-13JKVP-E
Height
(mm)
250
250
Width
(mm)
790
790
Dimension
Depth
(mm)
208
208
Net weight
(kg)
10
10
Fan motor output
(W)
30
30
Indoor unit
Air flow rate
(Cooling/Heating) (m³/h)
550/610
560/640
Unit model
RAS-10JAVP-E
RAS-13JAVP-E
Height
(mm)
550
550
Width
(mm)
780
780
Dimension
Depth
(mm)
270
270
Net weight
(kg)
38
38
Motor output
(W)
750
750
Type
Twin rotary type with DC-inverter variable speed control
Compressor
Model
DA91A1F-45F
DA91A1F-45F
Fan motor output
(W)
43
43
Outdoor unit
Air flow rate
(Cooling/Heating) (m³/h)
2150/2150
2410/2410
Type
Flare connection
Flare connection
Liquid side
Ø6.35
Ø6.35
Indoor unit
Gas side
Ø9.52
Ø9.52
Liquid side
Ø6.35
Ø6.35
Outdoor unit
Gas side
Ø9.52
Ø9.52
Maximum length (Per unit)
(m)
25
25
Maximum chargeless length
(m)
15
15
Piping
connection
Maximum height difference
(m)
10
10
Name of refrigerant
R410A
R410A
Refrigerant
Weight
(kg)
0.9
0.9
Power supply
3 Wires : includes earth (Outdoor)
3 Wires : includes earth (Outdoor)
Wiring
connection
Interconnection
4 Wires : includes earth
4 Wires : includes earth
Indoor
(Cooling/Heating)
(°C)
21–32/0–28
21–32/0–28
Usable temperature range
Outdoor (Cooling/Heating)
(°C)
10–43/–10–24
10–43/–10–24
Installation plate
1
1
Wireless remote controller
1
1
Batteries
2
2
Remote controller holder
1
1
Zeolite filter
1
1
Zeolite-3G filter
1
1
Mounting screw
6 (Ø4 x 25L)
6 (Ø4 x 25L)
Flat head wood screw
2 (Ø3.1 x 16L)
2 (Ø3.1 x 16L)
Plasma pure filter
1
1
Installation manual
1
1
Owner’s manual
1
1
Indoor unit
Pattern
1
1
Accessory
Outdoor unit Drain nipple
1
1
Содержание RAS-10JAVP-E
Страница 85: ... 85 MCC 813 ...
Страница 86: ... 86 12 EXPLODED VIEWS AND PARTS LIST 12 1 Indoor Unit 1 ...