– 17 –
5-2. Outdoor Unit
RAS-10JAVP-E, RAS-13JAVP-E
5. SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAS-10JKVP-E, RAS-13JKVP-E
No.
1
2
3
4
Parts name
Fan motor (for indoor)
Thermo. sensor (TA-sensor)
Heat exchanger temp. sensor
(TC-sensor)
Louver motor
Type
MF-280-30-1
( – )
( – )
MP24GA
Specifications
DC280–340V, 30W
10k
Ω
at 25°C
10k
Ω
at 25°C
Output (Rated) 1W, 16poles, 1phase DC12V
No.
1
2
3
4
5
6
7
8
9
Parts name
Reactor
Outside fan motor
Suction temp. sensor
(TS sensor)
Discharge temp. sensor
(TD sensor)
Outside air temp. sensor
(TO sensor)
Heat exchanger temp. sensor
(TE sensor)
Terminal block (6P)
Compressor
Compressor thermo.
Model name
CH-57
ICF-140-43-1
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA91A1F-45F
US-622KXTMQO-SS
Rating
L=10mH, 16A x 2
DC140V, 43W
10k
Ω
(25°C)
62k
Ω
(20°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
20A, AC250V
3-phases 4-poles 750W
OFF: 125 ± 4°C, ON: 90 ± 5° C