8-4-2. How to Cancel the Auto Restart Function
To cancel auto restart function, proceed as follows :
Repeat the setting procedure : the unit receives the signal and beeps three times.
The unit will be required to be turned on with the remote controller after the main power supply is turned off.
• When the system is on stand-by (not operating)
• When the system is operating
• While this function is being set, if the unit is in operation, the orange lamp is on.
Operation
Push [RESET] button for more than
three seconds.
Motions
The unit is on standby.
↓
The unit starts to operate.
The orange lamp is on.
↓
After approx. three seconds,
The unit beeps three times
The lamp changes from
and continues to operate.
orange to green.
If the unit is not required to operate at this time, push [RESET] button
once more or use the remote controller to turn it off.
Operation
Push [RESET] button for more than
three seconds.
Motions
The unit is in operation.
The orange lamp is on.
↓
The unit stops operating.
The orange lamp is turned off.
↓
After approx. three seconds,
The unit beeps three times.
If the unit is required to operate at this time, push [RESET] button
once more or use the remote controller to turn it on.
8-5-1. How to Turn Off Filter Check Lamp
Push [FILTER] button on the remote controller.
Or push [RESET] button on the indoor unit.
Then we have to clarify it.
NOTE :
If [RESET] button is pushed while the filter check
lamp is not indicating, the indoor unit will start the
automatic operation.
When you want a temporary operation while the filter
lamp lights, put out the lamp once, and then push
the RESET button.
8-4-3. Power Failure During Timer Operation
When the unit is in timer operation, if it is turned off
because of power failure, the timer operation is
cancelled. Therefore, set the timer operation again.
NOTE :
The Everyday Timer is reset while a command
signal can be received from the remote controller
even if it stopped due to a power failure.
8-5. Filter Check Lamp
When the elapsed time reaches 1000 hours after
filter operation, the filter check lamp indicates.
After cleaning the filters, turn off the filter check
lamp.